Technical data
Model series Model series 2
Container design with polycarbonate bowl
Condensate drain Semi-automatic
Thread G 1/2"
Container volumes [cm³] 49
Optimal flow* [l/min] 500
H [mm] 195
H1 [mm] 147
L [mm] 63
Mounting brackets W 2 F
Coupling kit KP 2 F
Coupling kit with wall bracket KPW 2 F
Replacement filter V 28/67
Input pressure [bar] 1.5 - 16
Further information on FV12F
Weight 440 g / Pcs
GTIN 4050571310608
Customs duty number 84213925
RoHS compliant Yes
Description - FUTURA prefilter, G 1/2", Model series 2
Materials:
Body: PA 66 GF60, seals: NBR, condensate container: polycarbonate
Temperature range:
-10°C bis +50°C
Input pressure:
1.5 - 16 bar (model series 0: 1.5 - 12 bar)
Condensate draining:
Semi-automatic** (activated carbon filter without drainage)
Media:
Compressed air, neutral gases
ATEX:
Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU (not model series 0 or differential pressure indicator / differential pressure gauge)
Advantages:
•simple assembly of single components using coupling kits within a model series.
Application:
Pre-filters are used where high requirements are placed for the purity of compressed air. Fine particles (> 0.3 µm), which can pass unhindered through the sintered filters, are separated here. Pre-filters are also installed in order to increase the service life of microfilters.
Dust removal:
> 0.3 µm (99.99 %)
Optional:
Version with metal bowl and inspection tube (model series 0: without inspection tube) -M, automatic discharge -AM, automatic discharge closed when not pressurised (0 to 16 bar, model series 0: 0 - 12 bar) -AMNC
*at 6 bar input pressure and 0,02 bar pressure loss, **As soon as the input pressure falls below the minimum. input pressure, the drain valve opens automatically. The semi-automatic drain valve can be prevented from opening by screwing the drain screw tight.
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.